TM-9-2350-261-20-1

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 1 OF 4

  TM-9-2350-261-20-1 - Page 280 of 346

TM 9-2350-261-20-1
LEFT REAR UTILITY OUTLET/BLOWER DOES NOT WORK
(M577A2 AND M1068 ONLY)
0045 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 43)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Personnel Required
Unit Mechanic
Helper (H)
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
MASTER SWITCH turned to ON (see your -10)
T
1.
Check to see if either the blower or the left rear utility
outlet are working.
2.
Does either the blower or the left rear utility outlet work?
TN
GO TO
BY
(PAGE 0045 00-3)
Y
1.
Check to see if the blower is operating normally.
2.
Does the blower operate normally?
YN
GO TO
CY
(PAGE 0045 00-4)
2Y
1.
Remove rear main harness circuit 37B plug (1) from left
rear utility outlet jack (2).
2.
Measure voltage between circuit 37B plug (1) and ground.
3.
Does multimeter read less than 17 volts?
2YN
1.
Turn MASTER SWITCH to OFF
(see your -10).
2.
Replace utility outlet receptacle
(WP 0332 00).
3.
Verify no faults found.
004500-1