TM 9-2350-261-20-1
RAMP WILL NOT LOWER
0062 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Personnel Required
Unit Mechanic
Helper (H)
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
D river ’s pow er plant access panel rem oved
(see your
-10)
Power plant rear access panels removed (see your -10)
Rear compartment floor plates removed (WP 0436 00),
(WP 0437 00), (WP 0438 00), (WP 0439 00),
(WP 0440 00), or (WP 0441 00)
T
Lowering ramp could injure personnel. Make sure no one
is in ramp zone before you lower ramp. If tactical situation
permits, sound horn before dropping ramp.
1.
Release ramp (see your -10).
2.
Observe ramp latches (1).
3.
Do ramp latches (1) release ramp?
TN
1.
Repair, replace and/or adjust
ramp latches and/or linkage (see
Chapter 25).
2.
Verify no faults found.