TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 445 of 1008

TM 9-2350-261-20-2
DISCONNECT/CONNECT BATTERY GROUND LEAD
0294 00
THIS WORK PACKAGE COVERS:
Disconnect (page 0294 00-1).
Connect (page 0294 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Battery Terminal Puller (WP 0780 00, Item 47)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Grease (WP 0782 00, Item 24)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Ramp lowered (see your -10)
All radios and heaters OFF (see your -10)
Battery access (see your -10)
Battery access cover removed (M1068 Only)
(WP 0297 00)
DISCONNECT
WARNING
Gas from batteries can explode. Ventilate compartment before you disconnect or connect
battery cables. Battery acid can burn or blind you. Do not get acid on your skin or eyes.
ALWAYS disconnect ground lead (circuit 7) first and connect it last.
WARNING
Battery posts and cables touched by metal objects can short circuit and burn you. Do not
wear jewelry, necklaces, or watches when working on the electrical system. Keep tools away
from posts, wires, and terminals.
029400-1