TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 450 of 1008

REPLACE BATTERY COVER AND GROUND LEAD (M113A2, M901A1,
AND M1059) — Continued
INSTALLATION
CAUTION
Battery cells can be damaged if the batteries are hooked up incorrectly. Make sure batteries
are hooked up correctly.
1.
Place two terminal lugs (4) on battery posts. Secure with two screws (6) and nuts (5).
2.
Place jumper lead (2) on two screws (3) of two terminal lugs (4). Secure with two nuts (1).
NOTE
Install circuits 6 and 48 positive leads before installing circuit 7 ground lead.
3.
Install circuit 7 lead (7) as follows:
a.
Place lead (7) on hull mount. Secure with two washers (8), screw (9), and nut (10).
b.
Install new grommet (11) in battery box (12). Route circuit lead 7 (7) through grommet into battery box.
c.
Place circuit 7 lead (7) on screw (3) in terminal lug (4) of battery closest to the ramp door. Secure with nut (1).
0295 00-4
0295 00
TM 9-2350-261-20-2