TM 9-2350-261-20-3
REPLACE RAMP CYLINDER BREATHER HOSE (M1064 ONLY) — Continued
0592 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Apply light coat of sealing compound to external tapered threads. Do not apply sealant beyond small end of external
tapered threads.
2.
Install elbow (4) in ramp cylinder (5).
3.
Install nipple (3) in elbow (4).
4.
Install coupling (2) on nipple (3).
5.
Install breather (1) in coupling (2).
0592 00-2