TM 9-2350-261-20-3
REPLACE 5.0 KW AUXILIARY POWER UNIT FUEL SHUTOFF VALVE (M577A2
AND M1068 ONLY) — Continued
0594 00
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
Apply light coat of sealing compound to all external tapered threads. Do not apply sealant beyond small end of tapered
threads.
2.
Install nipple (1) in tee (2).
3.
Install shutoff valve (3) on nipple (1).
4.
Place clamp (4) on nipple (1). Secure clamp to bracket (5) with screw (6) and new locknut (7).
5.
Install elbow (8) on shutoff valve (3).
6.
Connect hose (9) to elbow (8).
059400-3