TM 9-2350-261-20-4
REPLACE AC POWER EXTENSION BOX A19 (M1068 ONLY) — Continued
0720 00
INSTALLATION
1.
Install A.C. power extension box A19 (3), four washers (5), screws (4), and new locknuts (6) on mount (7).
2.
Connect cable W252 (1) to connector J15 (2) on A.C. power extension box A19 (3).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
END OF TASK
0720 00-2