TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 453 of 767

TM 9-2350-261-20-4
REPLACE POWER DISTRIBUTION CABLE (W3) (M1068 ONLY) — Continued
0739 00
INSTALLATION
1.
Install new W3 cable (1) in carrier.
2.
Connect cable W3 plug P1 (1) to jack J1 (2) on power distribution box A3 (3).
3.
Install four clamps (4) on cable W3 and secure to hull weldnuts with screws (5).
4.
Install six new tie straps (6) on cable W3.
5.
Connect cable W3 plug P3 (7) to jack J24 (8) on power distribution enclosure A1 (9).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Turn MASTER SWITCH to ON (see your -10). Check that electrical system works properly. See TM
11-7010-256-12&P.
3.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0739 00-2


Back to Top