TM 9-2350-261-20-4
REPLACE AC POWER EXTENSION CABLE (W8) (M1068 ONLY)
0744 00
THIS WORK PACKAGE COVERS:
Removal (page 0744 00-1).
Installation (page 0744 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Tie strap (16)
Personnel Required
Power-Generation Equipment Repairer 52D10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect cable W8 plug P11 (1) from power control box A1 jack J31 (2).
2.
Remove and discard 16 tie straps (3).
3.
Remove five screws (4) and loop clamps (5).
4.
Remove screw (6) and loop clamp (7).
5.
Disconnect cable W8 plug P1 (8) from curbside power box A7 jack J1 (9).
6.
Remove cable W8 from carrier.
074400-1