TM 9-2350-261-20-4
REPLACE CASCADE REMOTE HARNESS (M1068 ONLY)
0745 00
THIS WORK PACKAGE COVERS:
Removal (page 0745 00-1).
Installation (page 0745 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Locknut (4)
Lockwasher (10)
Lockwasher (10)
Personnel Required
Power-Generation Equipment Repairer 52D10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Remove faceplate (1) on inverter housing A2 (2) by removing ten screws (3) and lockwashers (4). Discard lockwashers.
2.
Loosen captive screws on connectors and disconnect RP1 harness (5) from inverters (6).
3.
Remove ten screws (7), and lockwashers (8), from faceplate (9). Lower faceplate (9) to gain access to RP1 harness
(5). Discard lockwashers.
4.
Remove four locknuts (10), screws (11), and RP1 remote harness (5) from faceplate (9). Remove harness. Discard
locknuts.
074500-1