TM 9-2350-261-34
REPAIR CURBSIDE AC POWER EXTENSION BOX A19 (M1068 ONLY) — Continued
0091 00
ASSEMBLY
1.
Install six connectors (10) on cover (2) with dust caps (11) and secure with 24 screws (8) and new locknuts (9).
2.
Install connector J15 (7) on extension box (4) and secure with four screws (5) and new locknuts (6).
NOTE
See wiring diagram (page 0091 00-4) for assembly/disassembly of wires to connectors.
3.
Connect leads to connectors if necessary.
4.
Install gasket (3) on extension box (4) with cover (2) and secure with four screws (1).
009100-3