TM 9-2350-261-34
FABRICATED TOOLS — Continued
0106 00
Special Purpose Power Cable for Power Control Enclosure (M1068 Only)
MATERIALS/PARTS REQUIRED
W3 Cable P/N 12383899
Plug WC596-13-3 or WC596/100-1
NOTES
1. Remove connector labeled W3 P1 (A3 J1) from W3 cable.
2. Cut cable to required length (for connecting power control enclosure to AC outlet).
WARNING
Incorrect polarity can harm personnel and damage equipment when power is applied to the
power control enclosure. Make sure polarity is correct when installing plug on cable.
3. Install new plug WC596-13-3 or WC596/100-1 on W3 cable. Connect per wiring diagram.
4. Purpose of cable is to connect the power control enclosure to shop AC power.
0106 00-2