VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068 ONLY) — Continued
0011 00
14Y
NOTE
1.
Measure resistance between K4 relay terminal X1 (1) and lead
8G to reversing contactor RC1-FWD terminal A1 (2).
2.
Does multimeter read 0 ohms?
14YN
1.
Replace lead 8G (WP 0084 00
and WP 0085 00).
2.
Verify no faults found.
0011 00-16
Use wiring diagram (see your -20).