NOTE
c
D
E
F
G
H
I
J
K
L
TM 9-2350-273-BD
COMMUNICATIONS SYSTEM
BUT
if the CALL light does not come on, the switch is in NORMAL.
Organizational or higher maintenance should then:
Remove R/T from mount, turn R/T upside down.
Remove bottom cover from R/T.
Loosen assembly A4000 captive screws.
Raise assembly A4000 and lock brace.
Turn X-MODE-NORMAL switch to X-MODE.
Be sure leaf springs are equally curved.
Lower assembly A4000 and tighten captive screws.
Be sure assembly hinge pin is pushed all the way in.
Replace bottom cover of R/T.
Replace R/T on to mount.
If the AUX receiver is to be used in the X-MODE communications hookup it
must be opened up and its switch set to X-MODE.
. .
The AUX receiver switch must be placed in NORMAL after you are through with
the X-MODE hook-up.
#10 - Loss of automatic channel selection if RT-246 is being used.