TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 186 of 889

TM 9-2350-277-10
DESCRIPTION AND USE OF OPERATOR’S CONTROLS AND INDICATORS — Continued
0004 00
Table 38. OLD MODEL AND NEW MODEL (MDL ONLY) FACEPLATES (M1068A3 ONLY)
KEY
CONTROL OR INDICATOR
FUNCTION
AC MAIN
Main Circuit Breaker for external AC power.
DC TO INVERTER CIRCUIT
BREAKER
Engages DC power to Inverters.
INVERTER CONTROL
Remote control box to the inverters.
INVERTER CONTROL ON/OFF
SWITCH
Turns power on or off to the inverters.
RESET SWITCH
Push (MDL) or slide (HEART/XANTRAX) and release to activate
inverters.
POWER LED INDICATOR
During normal operations only the power LED will remain on.
AC INVERTER CIRCUIT BREAKER
Controls 110 VAC power output from the inverters to the M1068
power system.
METER SELECT SWITCH
Switch between Main AC power and Inverter power.
INVERTER POWER LED
Indicates inverters are powering the M1068 power system.
0004 00-47
Change 5


Back to Top