TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 182 of 855

TM 9-2350-277-20-1
ENGINE CRANKS BUT WILL NOT START
0021 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Suitable Container
Personnel Required
Mechanic
Helper (H)
References
WP 0220 00
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access door open (TM 9-2350-277-10)
Driver’s power plant access panel removed
(WP 0441 00)
Power plant rear access panels removed (WP 0439 00)
T
1.
Inspect condition and operation of fuel cut off cable
assembly (WP 0220 00).
2.
Is cable assembly in good condition and in proper adjustment?
TN
1.
Replace and/or adjust fuel cut off
cable assembly (WP 0220 00).
2.
Verify no faults found.
Y
1.
Disconnect engine fuel return line (1) from quick
disconnect fitting (2).
2.
Depress plunger on quick disconnect fitting (1) in the engine
fuel return line. Catch fuel in suitable container.
3.
Crank engine with plunger depressed. Have helper assist.
4.
Does fuel flow out while cranking engine?
YN
GO TO
AY
(PAGE 0021 00-2)
002100-1
Change 5


Back to Top