TM 9-2350-277-20-1
TRANSMISSION DOES NOT HOLD 2ND POSITION
0068 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Electrical Connector Pliers (WP 0926 00, Item 31)
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Multimeter (WP 0926 00, Item 30)
Personnel Required
Mechanic
Helper (H)
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Transmission in 1-2 position
Power plant access door open (TM 9-2350-277-10)
T
1.
Remove harness 12349810 plug (1) from transmission jack (2).
2.
Turn MASTER SWITCH to ON. See TM 9-2350-277-10.
3.
Measure voltage between each socket on harness 12349810
plug (1) and ground. Multimeter should read 18 volts or
more at socket A (3), C (4), E (5), and G (6), and read 0
volts for all remaining sockets.
4.
Does multimeter read less than 18 volts at sockets A (3), C (4), E
(5), and G (6), or more than 0 volts at all remaining sockets?
TN
1.
Faulty transmission. Beyond unit
maintenance repair.
2.
Notify supervisor.
006800-1
Change 5