TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 481 of 855

TM 9-2350-277-20-1
NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 (M1068A3
ONLY)—Continued
0094 00
T
1.
With AC power accepted, set AC RIGHT OUTLETS switches (3)
on Power Control Enclosure panel to ON, see TM
11-7010-256-12&P.
2.
Measure voltage between sockets A and B of jack J31 (2).
3.
Measure voltage between sockets C and D of jack J31 (2).
4.
Does multimeter read 110 volts AC or more for both
measurements?
YES
NO
GO TO
BY
(PAGE 0094 00-4)
0094 00-2


Back to Top