TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 670 of 855

TM 9-2350-277-20-1
DCA CURRENT SHUNT DIAGNOSTIC TROUBLESHOOTING — Continued
0142 00
BY
1.
Remove plug W1 P2 (1) from MSD/ICE distribution
box jack J2 (2).
2.
Measure resistance between MSD/ICE distribution box
jack J2 (2), socket X (3) and Y (4).
3.
Does MSD read more than one ohm?
BYN
1.
Faulty W1 cable. Beyond unit
maintenance repair.
2.
Notify supervisor.
B2Y
1.
Remove harness 12354593 P1 (1) from MSD/ICE
distribution box jack J1 (2).
2.
Measure resistance between harness 12354593 P1 (1),
socket s (3) and m (4).
3.
Does MSD read more than one ohm?
B2YN
1.
Replace MSD/ICE distribution box
(WP 0874 00 thru WP 0877 00).
2.
Verify no faults found.