TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 665 of 855

TM 9-2350-277-20-1
DCA BATTERY VOLTAGE DIAGNOSTIC TROUBLESHOOTING — Continued
0141 00
Y
1.
Measure voltage between plug W1 P1 (1), pin V (+) (2) and
ground. MSD should read 22 volts or more.
2.
Set up Test 91. See TM 9-6625-2301-14&P.
3.
Measure voltage between plug W1 P1 (1), pin W (-) (3) and
ground. MSD should read 22 volts or more.
4.
Does MSD indicate a fault?
YN
1.
Faulty MSD.
2.
Notify supervisor.
2Y
1.
Remove plug W1 P2 (1) from MSD/ICE distribution
box jack J2 (2).
2.
Measure voltage between MSD/ICE distribution box jack
J2 (2), pins V (+) (3) and W (-) (4).
3.
Does MSD indicate other than battery voltage?
2YN
1.
Faulty W1 cable. Beyond unit
maintenance repair.
2.
Notify supervisor.
014100-2