TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 712 of 855

TM 9-2350-277-20-1
MSD/ICE TEST 32 AIR BOX PRESSURE DIAGNOSTIC
TROUBLESHOOTING — Continued
0147 00
3Y
1.
Remove harness 12354593 P1 (1) from MSD/ICE
distribution box jack J1 (2).
2.
Set up Test 92. See TM 9-6625-2301-14&P.
3.
Measure resistance between MSD/ICE distribution box jack
J2 (3), pin AB (4) and the following jack pins:
J2 (5), pin f (6)
J2 (5), pin g (7)
J1 (2), pins d (8)
J1 (2), pins j (9)
4.
Does MSD read between 3600 and 4400 ohms for each
measurement?
3YN
1.
Replace MSD/ICE distribution
box (WP 0874 00, WP 0875 00,
or WP 0877 00).
2.
Verify no faults found.
014700-3
Change 5


Back to Top