TM 9-2350-277-20-2
ADJUST COOLANT PUMP BELTS — Continued
0239 00
2.
Pryupwardontangofidlerpulleyassembly(5)toget1/4to3/8inchdeflectionondrivebelts(6)midwaybetween
pulleys (1) and (3) while applying a firm push with thumb. Tighten two screws (4).
3.
Check for proper tension by using straight edge (2) to measure deflection across drive belts at pulleys (1) and (3).
If tension meter is available, check 40-50 lbs (173–217 N) tension. If necessary, readjust tension. TORQUE TWO
SCREWS (4) TO 360-420 LB-IN (41-47 N·M). Use torque wrench and socket set.
FOLLOW-THROUGH STEPS
1.
Install power plant rear access panels (see your -10).
END OF TASK
0239 00-2
Change
4