TM 9-2350-277-20-3
REPLACE INSTRUMENT PANEL MOUNTS AND GROUND LEAD (NEW
CONFIGURATION) — Continued
0295 01
3.
Tip instrument panel forward and remove two screws (22), ground lead (1), ground lead circuit 519 (24), ground lead
circuit 369A (25), ground lead circuit 406B (23), two lockwashers (21), and resilient mounts (11) from instrument
panel. Discard lockwashers.
4.
Remove locknut (18), washer (17), lockwasher (20), ground lead (16), ground lead (19), screw (15), and long strut
(5) from hull mount. Discard lockwasher and locknut.
5.
Remove locknut (14), washers (13), screw (12), and strut (4) from hull mount. Discard locknut.
INSTALLATION
1.
Place strut (4) on hull mount. Secure with screw (12), washer (13), and new locknut (14). Do not tighten locknut.
2.
Place long strut (5) on hull mount. Secure with screw (15), new lockwasher (20), ground lead (19), ground lead (16),
washer (17), and locknut (18). Do not tighten locknut.
3.
Install ground lead (1), ground lead circuit 519 (24), ground lead circuit 369A (25), ground lead circuit 406B (23),
and two new lockwashers (21) on two screws (22). Insert screws thru instrument panel and secure with two resilient
mounts (11).
0295 01-2
Change 5