TM 9-2350-277-20-3
REPLACE MASTER SWITCH PANEL ASSEMBLY (M113A3, M1059A3,
M1064A3, AND M58 ONLY) — Continued
0260 00
3.
Remove screw (8), lockwasher (9), and ground lead (10) from negative post (11) of auxiliary power receptacle (12).
Remove ground lead (10) and grommet (13) from master switch panel assembly (6). Discard lockwasher and grommet.
4.
Remove screw (1), locknut (2), circuit 400 lead (3), circuit 2 lead (4), and circuit 6 lead (5) from conductor bus (6).
Remove circuit 6 lead (5) and grommet (7) from master switch panel assembly (8). Discard locknut and grommet.
5.
Remove nut (9), lockwasher (10), and circuit 2A lead (11) from master switch post (12). Discard lockwasher.
0260 00-2
Change 5