TM 9-2350-277-20-3
REPLACE MASTER SWITCH PANEL ASSEMBLY (M113A3, M1059A3,
M1064A3, AND M58 ONLY) — Continued
0260 00
6.
Install new grommet (1) on ground lead (2). Route ground lead into master switch panel assembly (3) and secure
grommet.
7.
Install ground lead (2) on negative post (4) of auxiliary power receptacle (5). Secure with screw (6) and new lockwasher
(7).
8.
Install master switch panel assembly (3) on distribution box (8). Secure with eight screws (9), washers (10), and new
locknuts (11).
9.
Connect circuit 37 lead (12) to connector (13).
026000-5
Change 5