REPLACE MASTER SWITCH TO DISTRIBUTION BOX LEAD (CIRCUIT 49) (M577A3 AND
M1068A3 ONLY) — Continued
0267 00
3.
Remove screw (10), lockwasher (11), and circuit 49 lead (8) from distribution box bus bar (12). Discard lockwasher.
4.
Remove circuit 49 lead (8) with two grommets (13) from master switch panel (4) and distribution box (5). Discard
grommets.
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Check circuit 49 lead for continuity. Replace bad lead.
0267 00-2