TM 9-2350-277-20-3
REPLACE DISTRIBUTION BOX (M113A3,M1059A3, M1064A3, AND M58 ONLY)
— Continued
0269 00
REMOVAL
1.
Remove screw (1), lockwasher (2), leads 27E, 10, 15, (3), and 450A (4) from bus bar (5) of distribution box (6). Remove
grommet (7). Discard lockwasher and grommet.
2.
Remove lead 400 (8) from distribution box (6).
3.
Remove circuit leads 2 (9), 2A (10), and two grommets (11) from distribution box (6). Discard grommets.
NOTE
Step 4 applies to M113A3 carriers with water/ration heater kit installed only.
4.
Remove circuit lead 222B (12) and grommet (13) from distribution box (6). Discard grommet.
0269 00-2
Change 2