TM-9-2350-277-20-3

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 3 OF 6

  TM-9-2350-277-20-3 - Page 114 of 941

TM 9-2350-277-20-3
0270 00
INSTALLATION
1.
Install two bilge pump circuit breakers (1) in distribution box (2). Secure with four screws (3) and new locknuts (4).
2.
Install two blocks (5) in distribution box (2). Secure with four screws (6) and new lockwashers (7).
NOTE
Do Step 3 for M113A3 carriers with water/ration heater kit installed only.
3.
Install water/ration heater circuit breaker (8) in distribution box (2). Secure with two screws (9) and new locknuts (10).
4.
Install distribution box (2) on hull. Secure with five screws (11) and new lockwashers (12).
0270 00-5
Change 2
REPAIR DISTRIBUTION BOX (M113A3,M1059A3, M1064A3, AND M58 ONLY) —
Continued