TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 322 of 1047

TM 9-2350-277-20-5
REPLACE PERSONNEL HEATER ASSEMBLY (M1064A3 ONLY) — Continued
0704 00
INSTALLATION
WARNING
Exhaust fumes can kill. Fumes must be vented. If the wrong heater is installed, fumes will not
be completely vented. Never substitute a “common air” heater for a “dual air” heater.
NOTE
For 5000-30178 heaters, the vent outlet seal must be replaced EVERY time the heater is
reinstalled into a vent ducting system. See TM 9-2540-207-14&P.
1.
Install plenum (1) on heater (2) with four new lockwashers (3) and screws (4).
2.
Install two mounts (5) on right wall mounts (6). Secure with four screws (7), three new lockwashers (8), ground strap
(9), and four new locknuts (10).
3.
Install two clamps (11) in two mounts (6).
4.
Slide clamp (12) on heater intake pipe (13) and clamp (14) on heater exhaust pipe (15). Place heater (2) and shield (16)
on mounts (5). Secure with two clamps (11).
0704 00-5
Change 3


Back to Top