TM 9-2350-277-20-5
REPLACE NBC AIR PURIFIER AND FRAME (M577A3 ONLY)
0776 00
THIS WORK PACKAGE COVERS:
Removal (page 0776 00-1).
Installation (page 0776 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Lockwasher (4)
Personnel Required
Unit Mechanic
References
See your -10
See FM 21-40
TM 3-6680-316-10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (WP 0338 00)
REMOVAL
WARNING
Contaminated filters are hazardous to personnel. Use precautions when handling filters (see
FM 21-40). Dispose of filters using trained chemical environment personnel.
1.
Disconnect power cable (1) from air purifier (2).
2.
Remove screw (3) and ground strap (4) from air purifier (2).
Reinstall screw (3) into air purifier
(2).
3.
Loosen two clamps (5) and remove two couplings (6) and clamps from air purifier (2).
0776 00-1
Change 2
NOTE
You may need to loosen clamps and turn hose tubes away to remove air purifier.