TM 9-2350-277-20-5
REPLACE M8A3 AIR PURIFIER AND FRAME (M1059A3 ONLY)
0778 00
THIS WORK PACKAGE COVERS:
Removal (page 0778 00-1).
Installation (page 0778 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Locknut (24)
Locknut (5)
Personnel Required
Unit Mechanic
References
See your -10
See FM 3-5
TM 3-6680-316-10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground strap disconnected (WP 0337 00)
REMOVAL
WARNING
Contaminated filters are hazardous to personnel. Use precautions when handling filters (see
FM 3–5). Dispose of filters using trained chemical environment personnel.
1.
Remove screw (1), two washers (2), locknut (3), and ground lead (4) from bracket (5).
2.
Disconnect power cable (6) from air purifier (7).
3.
Remove quick disconnect fittings of three hoses (9) from air purifier (7).
4.
Unfasten latch (10) and lift air purifier (7) from frame assembly (11).
5.
Remove five screws (12), ten washers (13), five locknuts (14), and frame assembly (11) from centers of five mounts (15)
and (16). Discard locknuts.
6.
Remove 15 screws (17), 30 washers (18), 15 locknuts (19), and 4 mounts (15) from bracket (5). Discard locknuts.
0778 00-1