TM-9-2350-277-20-6

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 6 OF 6

  TM-9-2350-277-20-6 - Page 441 of 487

TM 9-2350-277-20-6
INSTALL/REMOVE CHEMICAL AGENT AUTOMATIC ALARM KIT (M113A3 ONLY) —
Continued
0918 00
REMOVAL
1.
Disconnect power cable (1) plug 6B POS (2) from battery power lead socket (3).
2.
Remove screw (4), lockwasher (5), clamp (6) with cable (7), power cable (1) ground lead (8), two ground leads (9),
capacitor bracket (10), and lockwasher (11) from weldnut (12). Discard lockwashers.
3.
On weldnut (12), install new lockwasher (11), capacitor bracket (10), two ground leads (9), clamp (6) with cable (7), new
lockwasher (5), and screw (4).
0918 00-8


Back to Top