TM 9-2350-277-20-6
CONVERT PRIMARY POWER INVERTER TO SLAVE (ALL
EXCEPT OUTBACK)
0830 01
THIS WORK PACKAGE COVERS:
Convert Primary Power InvertertoSlave(page083001-1)
.
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Personnel Required
Power-Generation Equipment Repairer 52D10
References
WP 0338 00
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
All external power disconnected
(TM 11-7010-256-12&P)
Battery ground lead disconnected
(WP 0338 00)
CONVERT PRIMARY POWER INVERTER TO SLAVE
NOTE
By switching the W15 cable connectors, the faulty inverter becomes the slave and can stay
dormant, while the reassigned new primary inverter will function and provide 50% power
output (2.5 kW/20 amps maximum).
This procedure should only be used as a temporary repair until maintenance can replace
the faulty power inverter.
1.
Remove ten screws (1), lockwashers (2), and cover (4) from inverter housing (3). Discard lockwashers.
083001-1
Change 5