TM 9-2350-277-34
PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY) — Continued
0010 00
F3Y
1.
Measure resistance between pins (P1A or B thru 26A or B)
on connector J101 (1) and connector J102 (2) of External
Communication Box A11 (3) front panel as follows:
P1Atop1A
P1Btop1B
P2Atop2A
P2Btop2B
P3Atop3A
P3Btop3B
P4Atop4A
P4Btop4B
P5Atop5A
P5Btop5B
P6Atop6A
P6Btop6B
P7Atop7A
P7Btop7B
P8Atop8A
P8Btop8B
P9Atop9A
P9Btop9B
P10A to p10A
P10B to p10B
P11A to p11A
P11B to p11B
P12A to p12A
P12B to p12B
P13A to p13A
P13B to p13B
P14A to p14A
P14B to p14B
P15A to p15A
P15B to p15B
P16A to p16A
P16B to p16B
P17A to p17A
P17B to p17B
P18A to p18A
P18B to p18B
P19A to p19A
P19B to p19B
P20A to p20A
P20B to p20B
P21A to p21A
P21B to p21B
P22A to p22A
P22B to p22B
P23A to p23A
P23B to p23B
P24A to p24A
P24B to p24B
P25A to p25A
P25B to p25B
P26A to p26A
P26B to p26B
2.
Does multimeter read 0 ohms for each measurement?
F3YN
1.
Replace cable W117 (WP 0108 00).
2.
Verify no faults found.
F4Y
1.
Verify no faults found.
0010 00-13
Change 4