TM 9-2350-277-34
PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY) — Continued
0010 00
E2Y
1.
Remove cable W126 plug P1 (1) from roadside data
panel jack J3 (2).
2.
Measure resistance between sockets on P1 (1) and pins
on P108 (3) of cable W126 as follows:
Socket A to pin A
Socket B to pin B
Socket C to pin C
Socket D to pin D
Socket E to pin E
Socket F to pin F
Socket G to pin G
Socket H to pin H
Socket J to pin J
Socket K to pin K
Socket L to pin L
Socket M to pin M
Socket N to pin N
Socket P to pin P
Socket R to pin R
Socket S to pin S
Socket T to pin T
Socket U to pin U
Socket V to pin V
Socket W to pin W
Socket X to pin X
Socket Y to pin Y
Socket Z to pin Z
Socket a to pin a
3.
Does multimeter read 0 ohms for each measurement?
E2YN
1.
Replace cable W126. See TM
9-2350-277-20.
2.
Verify no faults found.
E3Y
1.
Verify no faults found.
0010 00-10
Change 4