7)
The sum found in Step 7a6 is your torque wrench setting. Set your dial.
NOTE
Setting the torque wrench dial at the reading found in Step 7a7 will deliver the required torque
at the end of your adapter.
Example: (Metric equivalents omitted for clarity).
1) 40 lb-ft required.
2) 12 inches.
3)12x40=480.
4) 4 inches.
5) 12 + 4 = 16 inches.
6) 480/16 = 30 lb-ft.
7) Torque wrench dial setting = 30.
Cleaning
8.
GENERAL CLEANING.
Cleaning is very important. All parts must be cleaned well and kept clean during
maintenance. Dirt or foreign matter can cause malfunctions and equipment failure. General cleaning procedures are
detailed in the following steps. Special cleaning procedures are covered in the task relating to the specific part. Clean
after repair and before assembly.
WARNING
Airpressureinexcessof30psi(207 kPa) can injure personnel. Do not direct pressurized air
at yourself or others. Always wear goggles.
CAUTION
Lyeorcausticsubstanceswilldamage metal surfaces. Do not use lye or caustic mixtures
to clean metal surfaces.
0014 00-4
Change 5