TM 9-2350-277-34
REPLACE ENGINE — Continued
0015 00
NOTE
Old and New Configuration refers to variable speed fan drive configurations.
REMOVAL
1.
Remove nut (8), lockwasher (9), ground lead (5) and circuit lead 771 (6) from generator (7). Discard lockwasher.
NOTE
Install covers on disconnected electrical cable connectors and components during maintenance.
Use tape, cloth, cardboard, or any appropriate material to prevent damage to components.
2.
Disconnect leads (3) from generator main cable (4).
3.
Disconnect lead (1) from airbox pressure transducer (2).
0015 00-2
Change 2