TM-9-2350-277-34

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-277-34 - Page 133 of 871

TM 9-2350-277-34
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0014 00
2)
If you cannot see the source of the leak, check the following items:
a)
Check that preformed gasket is not bent, or pinched.
b)
Check machined surfaces for fit and cleanliness.
3)
If leak persists, notify supervisor.
PREVENTIVE MAINTENANCE CHECKS AND SERVICES
There are no preventive maintenance checks and services (PMCS) or lubrication procedures required for the M113A3 FOV
Carriers at the direct support maintenance level. For crew level PMCS and lubrication procedures, see TM 9-2350-277-10.
For unit level PMCS and lubrication procedures, see TM 9-2350-277-20.
0014 00-14
Change 5


Back to Top