2--10 OPERATING PROCEDURES — CONTINUED
2--10.7
Operating Miscellaneous Items — Continued
b. Engine Air Cleaner
1
For summer position, when temperatures are over 40
°
F(4
°
C), leave locking handles (3) in holders.
2
For winter position, when temperatures are below 25
°
F(-
-4
°
C), raise locking handles (3) and fasten on
hooks (4).
3
For intermediate temperatures between 25 to 40
°
F(-
-4to4
°
C), start engine with locking handles (3) in
winter position. When engine reaches operating temperature, place locking handles in summer position.
4
An air cleaner indicator (5) is located alongside the left air cleaner. It reads less than 25 in. H
2
O when
air cleaner is operating properly. When airflow is restricted, the gage reads 25 in. H
2
O or greater
indicating that the air cleaner element should be serviced (para 3--5.4). The air cleaner indicator gage
locks into position every 5 in. H
2
O. A reset button on the bottom of the air cleaner indicator gage must
be pushed to zero the gage.
NOTE
Air cleaner shown in winter position.