TM-9-2350-311-10

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; OPERATOR’S MANUAL

NOVEMBER 1994

  TM-9-2350-311-10 - Page 397 of 775

TM 9-2350-311-10
2–22 EMERGENCY PROCEDURES — NUCLEAR, BIOLOGICAL, AND CHEMICAL (NBC)
DECONTAMINATION — CONTINUED
d. Chemical Agent Monitoring
Use the Chemical Agent Monitor as directed in the accompanying instructions or refer to TM 3-6665-327-13&P for
operating and maintenance instructions. If other chemical agent detection devices are used, follow accompanying
instructions.
e. Complete Howitzer Decontamination
When time permits, decontaminate complete howitzer (FM 3-5).
2-291/(2-292 blank)