TROUBLESHOOTING — CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PERSONNEL HEATER (GLOBAL A20)
12.A NO PERSONNEL HEATER OPERATION, NO FAULT LAMP OPERATION, NO DIAGNOSTIC CODE
DISPLAY
Step 1. Check MS power connection.
Tighten connector.
Step 2. Restart heater.
Step 3. If problem still exists, notify unit maintenance (NO PERSONNEL HEATER OPERATION, NO FAULT
LAMP OPERATION, NO DIAGNOSTIC CODE DISPLAY).
12.B C3, VENT FAN FAULT
Step 1. Check for frost or obstruction in vent fan.
Remove frost or obstruction.
Step 2. Start personnel heater.
Step 3. If problem still exists, notify unit maintenance (C3, VENT FAN FAULT).
12.C E1, LOW VOLTAGE
Step 1. Check for loose cable connection.
Tighten loose cable connection.
Step 2. If problem still exists, notify unit maintenance (E1, LOW VOLTAGE).
12.D E3, LOW BURNER AIR FLOW
Step 1. Check exhaust for restrictions.
Remove restriction from exhaust.
Step 2. Check for combustion air restriction.
Remove combustion air restriction.
Step 3. Restart personnel heater. If problem still exists, notify unit maintenance (E3, LOW BURNER AIR
FLOW).
12.E F1, IGNITION OVERTIME
Step 1. Check fuel supply.
Add fuel if necessary.
Step 2. Restart heater.
Step 3. If problem still exists, notify unit maintenance (F1, IGNITION OVERTIME).