TM 9-2350-311-10
G-3
LUBRICATION INSTRUCTIONS - CONTINUED
14. CHECK BALLS AND METERING HOLES (C) (11578385) -CONTINUED
NOTE
Use rag to catch ten check balls when sliding valve ring forward.
d.
Slide valve ring (45) forward and remove 10 check bails (46).
e.
Thoroughly wet check balls (46), vent seats (47), and metering holes (48) with CLP (item 8, Appx D) using the bore
evacuator brush.
f.
Apply a light coat of GMD (item 19, Appx D) or GGP (item 18, Appx D) to check balls (46), valve ring (45), and
unpainted cannon tube (44) surface before assembling.
G-18 Change 2