TM 9–2350–311–20–2
3–18
3–3
TROUBLESHOOTING CHART — CONTINUED
b.
CANNON — CONTINUED
(2)
EXCESSIVE RECOIL FORCE. — CONTINUED
Check hydraulic pressure on replenisher pressure
gage (TM 9–2350–311–10).
Is replenisher pressure 17–24 psi (117.215–165.48 kpa)?
CONTINUED FROM STEP B
yes
no
Repeat procedures in step
C. If recoil cylinder cannot
be bled, notify support
maintenance.
CONTINUED ON NEXT PAGE
yes
no
C
D
1.
Using manual elevation handle, depress
cannon assembly to maximum depression
(TM 9–2350–311–10).
2.
Loosen right-hand bleed plug and bleed
trapped air from rear of buffer. Tighten
right-hand bleed plug when air-free fluid flows
(TM 9–2350–311–10).
3.
Using manual elevation handle, elevate cannon
assembly to 50 mils (TM 9–2350–311–10).
4.
Loosen left-bleed plug and bleed trapped air
from front of buffer. Tighten left-hand bleed plug
when air-free fluid flows (TM 9–2350–311–10).
5.
Using manual elevation handle, elevate cannon
assembly to 180 mils (TM 9–2350–311–10).
6.
Loosen bleed plug on bleeder tee and bleed
trapped air until air-free fluid flows. Tighten
bleed plug (TM 9–2350–311–10).
Does air-free fluid flow?
Add hydraulic fluid, bleed
system, and check for leaks
(TM 9–2350–311–10).