TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 129 of 828

TM 9–2350–311–20–2
3–20
3–3
TROUBLESHOOTING CHART — CONTINUED
b.
CANNON — CONTINUED
(3)
EXCESSIVE RECOIL TRAVEL AT HIGH
ANGLE OF FIRE.
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
References
TM 9–2350–311–10
CONTINUED ON NEXT PAGE
1.
Using manual elevation handle, depress
cannon assembly to maximum depression
(TM 9–2350–311–10).
2.
Loosen right-hand bleed plug and bleed
trapped air from rear of buffer. Tighten
right-hand bleed plug when air-free fluid flows
(TM 9–2350–311–10).
3.
Using manual elevation handle, elevate cannon
assembly to 50 mils (TM 9–2350–311–10).
4.
Loosen left-bleed plug and bleed trapped air
from front of buffer. Tighten left-hand bleed plug
when air-free fluid flows (TM 9–2350–311–10).
5.
Using manual elevation handle, elevate cannon
assembly to 180 mils (TM 9–2350–311–10).
6.
Loosen bleed plug on bleeder tee and bleed
trapped air until air-free fluid flows. Tighten
bleed plug (TM 9–2350–311–10).
Does air-free fluid flow?
A
B
Perform inspection of variable recoil
(TM 9–2350–311–10).
Do index arrows begin to separate at 617 mils and 723
mils?
yes
no
Notify support mainte-
nance.


Back to Top