TM 9–2350–311–20–2
3–28
Change 2
3–3
TROUBLESHOOTING CHART — CONTINUED
b.
CANNON — CONTINUED
(6)
CAB FILLS WITH SMOKE OR GASES AFTER
FIRING.
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
References
TM 9–2350–311–10
Inspect obturator pad for serviceability
(TM 9–2350–311–10).
Is obturator pad serviceable?
Inspect and clean bore evacuator, bearing balls,
orifices, and valve rings for serviceablity
(TM 9–2350–311–10).
Are parts serviceable?
A
yes
no
Replace defective parts
(TM 9–2350–311–10).
B
yes
no
Fire cannon in accordance with
TM 9–2350–311–10.
Does smoke or gases fill cab after firing?
C
Replace obturator pad
(para 5–7).
Verify fault is corrected.
Continue normal opera-
tions.
yes
no
Notify support
maintenance.
END OF TASK