TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 145 of 828

TM 9–2350–311–20–2
3–36
3–3
TROUBLESHOOTING CHART — CONTINUED
c.
CAB TRAVERSING SYSTEM — CONTINUED
(1)
CAB WILL NOT TRAVERSE UNDER POWER
OR MANUALLY, BUT HYDRAULIC PRESSURE
IS NORMAL AND CAB LIGHTING OPER-
ATES.– CONTINUED
Replace wire 825A from
gunner’s selector switch
box assembly to bypass
valve assembly (para 8–7).
1.
Turn MASTER and CAB POWER switches to
OFF.
2.
Disconnect harness from J2 connector at
gunner’s selector switch box assembly.
3.
Place one multimeter lead on output terminal
3 of TRAVERSE CONTROL switch and the
other lead to pin C of J2 connector.
4.
Check for continuity.
Is continuity present?
E
yes
no
CONTINUED FROM STEP D
OUTPUT TERMINAL
GUNNER’S
SELECTOR
SWITCH BOX
ASSEMBLY
J2 CONNECTOR
+
TRAVERSE
CONTROL
SWITCH
Replace wire from TRAV-
ERSE CONTROL switch
to pin C of J2 connector
(para 8–12).
PIN C
CONTINUED ON NEXT PAGE


Back to Top