TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 396 of 828

TM 9–2350–311–20–2
6–74
6–28 LINES AND FITTINGS FROM MANUAL ACCUMULATOR ASSEMBLY
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
Materials/Parts
Cap and plug set (item 7, Appx D)
Plastic bag (item 4, Appx D)
Preformed packing (item 48, Appx G)
Preformed packing (item 46, Appx G)
Tag, marking (item 36, Appx D)
Equipment Condition
Discharge hydraulic pressure (para 6–3)
a.
Removal
WARNING
Do not torque hydraulic fittings or perform removal procedures when hydraulic system is pres-
surized. Discharging hydraulic system pressure before performing any maintenance proce-
dures will avoid serious injury to personnel.
Eye protection will be worn when performing maintenance procedures on all hydraulic compo-
nents to avoid injury to personnel.
CAUTION
All hydraulic lines and ports must be capped to prevent contaminants from entering the hydrau-
lic system and causing internal damage to hydraulic components.
All serviceable components must be placed in plastic bags to prevent contamination of hydraulic
system during installation.
NOTE
All hydraulic lines and components must be tagged before removal for identification during in-
stallation.
The removal of hydraulic tubes and fittings must be restricted to those items that are to be re-
placed. Therefore, the legends in this chapter are for identification only.
For removal, follow illustration and legend as a guide. Discard all preformed packings.
b.
Installation
CAUTION
When installing any hydraulic fitting, tighten fitting to aline with the connecting lines. Repositioning
can loosen threads, cause leaks, and damage preformed packings.


Back to Top