TM 9–2350–311–20–2
J–4
Change 2
NOTE
Perform steps 9 and 10 if pipe nipple and quick disconnect coupling have not been installed on
pump.
9
Apply teflon pipe sealant to threads of pipe nipple (21). Install pipe nipple in outlet port on electric hydraulic
pump (22).
10
Connect quick disconnect coupling (23) to pipe nipple (21).
11
Attach one end of hose assembly (24) to cylinder support assembly (1) and quick disconnect coupling (23).
NOTE
Hand pump hydraulic fluid capacity is 2 gallons (7.4 l) Electric hydraulic pump fluid capacity is 3/4
gallon (2.8 l).
12
Fill electric hydraulic pump (22) reservoir with hydraulic fluid (item 20.1, Appx D) to the proper level.
13
Connect electric hydraulic pump (22) to an electrical power source.
1
24
21
22
23