TM-9-2350-311-34-2

CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS HOWITZER, MEDIUM, SELF-PROPELLED, 155MM

TECHNICAL MANUAL; DIRECT AND GENERAL SUPPORT MAINTENANCE MANUAL

SEPTEMBER 1994

  TM-9-2350-311-34-2 - Page 119 of 552

TM 9-2350-311-34-2
CONTINUED
FROM STEP E
Check nitrogen pressure in primary accumulator
assemblv (TM 9-2350-311-20-2).
I
Is pressure between 850 to 900 psi (5861 to 6206 kPa)?
I
Charge primary accumula-
tor assembly (TM 9-2350-
311-20-2).
If charge does
not hold, repair or replace
primary accumulator
as-
sembly (para 6-8).
Check nitrogen pressure in secondary accumulator
Is pressure between 1450 to 1550 psi (9998 to 10687 kPa)?
I
I
Charge secondary accumu
lator assembly (TM 9-
2350-311-20-2).
If charge
does not hold, repair or re-
place secondary accumula-
tor assembly (para 6-9).
Replace safety relief eleva-
tion valve assembly
(para 6-12).
ASSEMBLY
I
\
AFETY RELIEF
EVATION VALVE
ASSEMBLY
------a
I
PRIMARY ACCUMULATOR
ASSEMBLY
END OF TASK