Description:
Jumper Wires
NOTE
This jumper wire is not for use with test jack connectors.
It can short-circuit equipment.
(For test
jack jumper wire, see procedure being performed.)
Materials/Tools:
Wire, electrical, 10 AWG (scavenge from available source)
Jumper Wires Fabrication/Test Procedure:
1.
Strip 1/2-inch of insulation from both ends of wire.
2.
Twist ends for insertion directly into connector sockets and tape in place.
NOTE
If wire is a larger AWG than required, do step 3.
If wire is a smaller AWG than required, do step 4.
3.
Pull back strands as required and clip off; tape over exposed wire and tape in place.
4.
Strip more insulation from ends, fold ends over until proper size is obtained, and tape in place.